(1) The radiation intensity of the ultraviolet lamp gradually decreases with the passage of time, so the intensity of the ultraviolet light should be measured regularly, and once it drops below the requirement, it should be replaced in time.


(2) The service life of the ultraviolet disinfection lamp, that is, the time to reduce the intensity of the new lamp to 70μW/cm2 (power≥30w), or the time to reduce to 70% of the intensity of the new lamp (power<30W), should not be less than 800h.


(3) The ultraviolet anti-virus lamp is a high-intensity ultraviolet anti-virus lamp: the intensity required to radiate 253.7nm ultraviolet light (measured at a vertical distance of 1m from the center of the tube) is: power 30w lamp, >170μW/cm2; 11W lamp, >40μW/cm2.